b'L oadc eLLs ensorsStarrett offers a full range of precision load cell sensors for material testing, force analysis and force measurement applications. Starrett load cells are compliant with IEEE 1451.4 and meet or exceed ASTM E4, BS 1610, ISO 7500-1 and EN 10002-2. Measurement accuracies of 0.05% of reading down to 1/100 of sensor capacity may be achieved. Sensors are supplied with a NIST-traceable Certificate of Calibration. bLc L oadc eLLs ensorsStarrett BLC load cell sensors are full-bridge, temperature compensated, strain gage instruments designed and optimized for basic force testing applications. These S-beam sensors feature high axial stiffness and minimal deflection at full capacity which leads to improved measurement accuracy.eLLs oadThe BLC sensors are general purpose sensors available in capacities from 2lbf to 500lbfC L (10 to 2500N). These sensors are used exclusively with FMM motorized test frames.BLC - Basic Force Measurement S-beam SensorsLoad Capacity Safe Overload Full Scale Deflection Height Width ThreadModel No. N KGF LBF % Full Scale in mm in mm in mm mmBLC-2 10 1 2 150 0.009 0.22 3.0 76.2 3.0 76.2 M6 x 1-6HBLC-5 20 2 5 150 0.008 0.21 3.0 76.2 3.0 76.2 M6 x 1-6HBLC-10 50 5 10 150 0.007 0.18 3.0 76.2 3.0 76.2 M6 x 1-6HBLC-20 100 10 20 150 0.007 0.18 2.0 50.8 2.0 50.8 M6 x 1-6HBLC-50 250 25 50 150 0.006 0.15 2.0 50.8 2.0 50.8 M6 x 1-6HBLC-100 500 50 110 150 0.003 0.08 2.0 50.8 2.0 50.8 M6 x 1-6HBLC-200 1000 100 225 150 0.003 0.08 2.0 50.8 2.0 50.8 M6 x 1-6HBLC-500 2500 250 550 150 0.005 0.13 2.0 50.8 2.0 50.8 M12 x 1.75-5HNOTESLoad measurement accuracy is 0.1% of load cell capacity. Display resolution is 10,000:1.Starrett recommends on-site verification of accuracy during installation. Sensor calibration should be performed at least annually.MLc L oadc eLLs ensorsThe Starrett MLC load cell sensors are full-bridge, temperature compensated,strain gage instruments designed and optimized for material testing applications.These low profile sensors feature high axial stiffness and minimal deflection at full capacity which leads to improved measurement accuracy.The MLC are general purpose sensors available in capacities from 125N to 50kN. For FMS, MMS, FMD, or MMD test frames.MLC Series - Low Profile SensorsLoad Capacity Safe Overload Full Scale Deflection Height 1 Width ThreadModel Number N KGF LBF % Full Scale mm inch mm inch mm inch mmMLC-125 125 12.5 28 150 0.08 0.003 38.1 1.5 69.8 2.75 M6 x 1-6HMLC-250 250 25 56 150 0.08 0.003 38.1 1.5 69.8 2.75 M6 x 1-6HMLC-500 500 50 112 150 0.08 0.003 38.1 1.5 69.8 2.75 M6 x 1-6HMLC-1000 1000 100 225 150 0.08 0.003 38.1 1.5 69.8 2.75 M6 x 1-6HMLC-1500 1500 150 337 150 0.03 0.001 63.51 2.51 104.8 4.13 M16 x 2-4HMLC-2500 2500 250 562 150 0.03 0.001 63.51 2.51 104.8 4.13 M16 x 2-4HMLC-5K 5000 500 1124 150 0.03 0.001 63.51 2.51 104.8 4.13 M16 x 2-4HMLC-10K 10,000 1000 2248 150 0.03 0.001 63.51 2.51 104.8 4.13 M16 x 2-4HMLC-25K 25,000 2500 5620 150 0.05 0.002 63.51 2.51 104.8 4.13 M16 x 2-4HMLC-50K 50,000 5000 11,250 150 0.05 0.002 63.51 2.51 104.8 4.13 M16 x 2-4HNOTES1 Dimension includes the base adapter. These MLC sensors are supplied with the base adapter standard.Base adapters are recommended for any MLC sensor.Load measurement accuracy is 0.05% of reading down to 1/100 of load cell capacity. Display resolution is 10,000:1.Starrett recommends on-site verification of accuracy during installation. Sensor calibration should be performed at least annually.62'