b'L oadc eLLs ensorsFLc L oadc eLLs ensorsThree models of s-beam load cell sensors are also available. These are all full bridge,temperaturecompensatedstraingageinstruments,designedforforce measurement applications, but suitable for some material testing applications. For FMS, MMS, FMD, or MMD test frames.P reMiuMM odeLsIdeal for low load applications, these sensors have a safe overload rating of 1000% of the sensor\'s load capacity.s eaLedM odeLsThese models are suitable for applications in non-laboratory environments where eLLs oaddirt, oil, dust and debris may be present.e conoMyM odeLs C LWhen price is an issue, these general purpose load cell sensors are economical and suitable for most general purpose force measurement applications.FLC-P Series - "Premium" S-beam SensorsLoad Capacity Safe Overload Full Scale Deflection Height Width ThreadModel Number N KGF LBF % Full Scale mm inch mm inch mm inch mmFLC-5P 5 0.5 1 1000 0.4 0.014 63.0 2.48 59.2 2.33 M6 x 1-6HFLC-10P 10 1 2 1000 0.3 0.012 63.0 2.48 59.2 2.33 M6 x 1-6HFLC-25P 25 2.5 5 1000 0.3 0.012 63.0 2.48 59.2 2.33 M6 x 1-6HFLC-50P 50 5 11 1000 0.2 0.009 63.0 2.48 59.2 2.33 M6 x 1-6HFLC-100P 100 10 22 1000 0.2 0.009 63.0 2.48 59.2 2.33 M6 x 1-6HFLC-250P 250 25 56 1000 0.2 0.009 63.0 2.48 59.2 2.33 M6 x 1-6HNOTESLoad measurement accuracy is 0.1% of load cell capacity. Display resolution is 10,000:1.Starrett recommends on-site verification of accuracy during installation. Sensor calibration should be performed at least annually.FLC Series - "Sealed" S-beam SensorsLoad Capacity Safe Overload Full Scale Deflection Height Width ThreadModel Number N KGF LBF % Full Scale mm inch mm inch mm inch mmFLC-500 500 50 112 150 0.10 0.004 63.0 2.5 50.8 2.0 M6 x 1-6HFLC-1000 1000 100 225 150 0.15 0.006 63.0 2.5 50.8 2.0 M6 x 1-6HFLC-2000 2000 200 450 150 0.13 0.005 76.2 3.0 50.8 2.0 M12 x 1.75-5HFLC-2500 2500 250 562 150 0.13 0.005 76.2 3.0 50.8 2.0 M12 x 1.75-5HFLC-5KN 5000 500 1124 150 0.13 0.005 76.2 3.0 50.8 2.0 M12 x 1.75-5HNOTESLoad measurement accuracy is 0.1% of load cell capacity. Display resolution is 10,000:1.Starrett recommends on-site verification of accuracy during installation. Sensor calibration should be performed at least annually.FLC-E Series - "Economy" S-beam SensorsLoad Capacity Safe Overload Full Scale Deflection Height Width ThreadModel Number N KGF LBF % Full Scale mm inch mm inch mm inch mmFLC-50E 50 5 11 150 0.08 0.003 63.5 2.5 50.8 2.0 M6 x 1-6HFLC-100E 100 10 22 150 0.08 0.003 63.5 2.5 50.8 2.0 M6 x 1-6HFLC-200E 200 20 45 150 0.08 0.003 63.5 2.5 50.8 2.0 M6 x 1-6HFLC-500E 500 50 112 150 0.10 0.004 63.5 2.5 50.8 2.0 M6 x 1-6HFLC-1000E 1000 100 225 150 0.15 0.006 63.5 2.5 50.8 2.0 M6 x 1-6HFLC-2000E 2000 200 450 150 0.15 0.006 76.2 3.0 50.8 2.0 M12 x 1.75-5HFLC-2500E 2500 250 562 150 0.13 0.005 76.2 3.0 50.8 2.0 M12 x 1.75-5HFLC-5000E 5000 500 1124 150 0.13 0.005 76.2 3.0 50.8 2.0 M12 x 1.75-5HNOTESLoad measurement accuracy is 0.1% of load cell capacity. Display resolution is 10,000:1.Starrett recommends on-site verification of accuracy during installation. Sensor calibration should be performed at least annually.starrett.com 63'